Get your free copy of customized energy mix card

  • Home
  • OA Consultancy:
    • THIRD PARTY PURCHASE[TPP]
    • GROUP CAPTIVE [GCP]
    • CAPTIVE [CPP]
    • REC & I-REC
  • CARBON ADVISORY
    • Carbon Offsets advisory
    • Carbon Credit Advisory
    • CO2 Footprint Calculation
  • PROJECTS
    • Consulting Services -Land
    • Land Aggregation
  • Blogs & Information
    • Blogs
  • AUDITS
    • Energy Audit
    • Fire & Safety Audit
  • FIRE & SAFETY
    • Fire Doors
  • CONTACT US
  • Comprehensive Audits
  • More
    • Home
    • OA Consultancy:
      • THIRD PARTY PURCHASE[TPP]
      • GROUP CAPTIVE [GCP]
      • CAPTIVE [CPP]
      • REC & I-REC
    • CARBON ADVISORY
      • Carbon Offsets advisory
      • Carbon Credit Advisory
      • CO2 Footprint Calculation
    • PROJECTS
      • Consulting Services -Land
      • Land Aggregation
    • Blogs & Information
      • Blogs
    • AUDITS
      • Energy Audit
      • Fire & Safety Audit
    • FIRE & SAFETY
      • Fire Doors
    • CONTACT US
    • Comprehensive Audits

  • Home
  • OA Consultancy:
    • THIRD PARTY PURCHASE[TPP]
    • GROUP CAPTIVE [GCP]
    • CAPTIVE [CPP]
    • REC & I-REC
  • CARBON ADVISORY
    • Carbon Offsets advisory
    • Carbon Credit Advisory
    • CO2 Footprint Calculation
  • PROJECTS
    • Consulting Services -Land
    • Land Aggregation
  • Blogs & Information
    • Blogs
  • AUDITS
    • Energy Audit
    • Fire & Safety Audit
  • FIRE & SAFETY
    • Fire Doors
  • CONTACT US
  • Comprehensive Audits

Multi-Use Retail Mall with multiplex and food court

An energy audit for a shopping mall with a multiplex and food court is a thorough, systematic process focused on identifying, quantifying, and reducing energy consumption in a complex, high-footfall environment. A detailed guide and expanded case study are provided below, with emphasis on methodology, execution, findings, and actionable improvements. Our energy audits provide a comprehensive analysis of your energy usage. We identify energy savings opportunities to reduce your energy consumption and lower your energy bills.

Expanded Audit Process Overview

1. Data Collection & Stakeholder Engagement

 

  • Collect historical utility data: Gather 1-3 years of electricity, gas, and water bills to understand baseline consumption patterns.
  • Interview staff and management: Get operational insights, schedules, and pain points, especially for food court vendors, maintenance teams, and multiplex managers.
  • Walkthrough survey: A physical inspection identifies visible inefficiencies, system age, insulation, and lighting/ventilation design.

2. Detailed Measurement & Instrumentation

 

  • Zone-wise metering: Deploy portable meters in major loads (HVAC, lighting, kitchen, escalators, multiplex screens).
  • Data logging: Use loggers and analyzers for continuous measurement across peak and off-peak periods.
    • E.g., measure multiplex projector loads or kitchen ventilation at lunch/dinner rush.

     

  • Specialized equipment (make & models):
    • Power Quality Analyzer: Fluke 435 II
    • Clamp Meter: Hioki 3280-10F
    • Thermal Imaging Camera: FLIR E8-XT
    • Lux Meter: HTC LX-101A
    • Humidity/Temperature Data Logger: Testo 174H
    • Flue Gas Analyzer (for food court exhaust): Testo 320.
  • Sub-metering: Where possible, temporary submeters on tenants, food court, cinema, and common area circuits for granular mapping.

3. Consumption Analysis & Benchmarking

 

  • Energy Profiling: Use logged data to construct hourly/daily load curves.
  • Benchmarking: Compare consumption per square foot to national mall or multiplex averages (mall range: 15–25 kWh/sq.ft./yr).
  • Identify high-usage clusters: Find out which zones (cinema, kitchen, common areas) have peaks and why (e.g., HVAC overuse, old kitchen equipment, continuous lighting in multiplex).

4. Diagnosis & Opportunity Identification

 

  • Analyze for anomalies: Find areas with unexpected peaks or slowdowns, such as undersized ventilation or unzoned HVAC.
  • System simulation: Use modeling tools to simulate savings from possible upgrades or control changes.
  • Cross-reference with standards: ASHRAE, BEE, or local efficiency standards for compliance check.

5. Findings and Recommendations

 

Key Findings

  • High usage in lighting: Much of the mall and multiplex areas often use outdated fluorescent or incandescent bulbs.
  • Inefficient HVAC: Central systems lack zoning, VFD controls, or are not maintained regularly.
  • Kitchen Energy Waste: Food court exhaust, refrigeration, and cooking lack controls or routine maintenance.
  • Escalators/Elevators: Often run regardless of traffic, lacking demand-based control.
  • Peak-hour Spikes: Coincide with movie showtimes, meal times, or events.

 

Recommendations

  • Upgrade all lighting to LED with occupancy/motion sensors in restrooms, corridors, staff areas.
  • Retrofit HVAC units with variable frequency drives, demand-based ventilation, and smart controls for multiplex/food court zoning.
  • Kitchen equipment: Replace with ENERGY STAR-rated models, install variable speed exhausts and optimize refrigeration cycles.
  • Integrate a Building Management System (BMS) for real-time monitoring and automation.
  • Implement sub-metering for tenant accountability and detailed tracking.

 

  • Staff training: Develop standard operating procedures, encourage off-peak maintenance, and run awareness campaigns.

 

  • Investigate rooftop solar for common area electricity use and promote renewable adoption.
  • Regular review: Repeat audits periodically to catch “drift” and ensure savings persist.

6. Implementation and Monitoring

 

  • Phased upgrades: Quick wins (LEDs, sensors) followed by deeper retrofits (HVAC, kitchen).
  • Contractor and vendor selection: Choose reputed suppliers for LED, HVAC, kitchen, and BMS (e.g., Philips Lighting, Voltas, Blue Star, Schneider Electric).
  • Metrics for success: Use sub-metered data to track real post-implementation savings.
  • Tenant engagement: Coordinate upgrades in leased spaces and introduce green lease clauses.

7. Timeframe

 

  • Typical comprehensive audit: 2–4 weeks, depending on mall size and complexity.
    • Data collection and survey: 3–5 days
    • Measurement/logging: 7–10 days (to capture weekday/weekend variations)
    • Analysis and reporting: 7–10 days.

Case Study Insights

 

Multiplex Example (Indore)

  • Replacing all cinemas’ and common area lighting with LEDs produced rapid, measurable energy and cost savings.
  • Targeted HVAC optimization in multiplex screens and games area improved comfort while reducing chiller runtime.
  • Combined, these steps reduced total consumption and provided ~12–18% direct energy cost reduction within a year.

 

Shopping Mall Example (Mumbai)

  • Identified outdated lighting and centralized HVAC as top inefficiency drivers.
  • Smart automation upgrades for lighting and HVAC led to cost-effective savings, justifying investments via reduced payback periods (often under three years).
  • Sub-metering and energy monitoring allowed granular tracking and further optimization.

Lessons & Strategic Guidance

 

  • Continuous Monitoring: Consumption patterns shift with tenant changes, new equipment, or evolving customer footfall; monitoring ensures persistent efficiency.
  • Holistic Approach: Savings are maximized when technical upgrades are paired with awareness and behavior change across management, staff, and tenants.
  • Stakeholder Buy-in: Early engagement with all facility stakeholders smooths implementation and ensures persistent energy-saving behavior.
  • Future Readiness: Plan for integration of EV charging or renewables as part of long-term sustainable strategy.

A methodical, data-driven, and inclusive audit delivers both bottom-line savings and environmental advantage, making malls, multiplexes, and food courts future-ready and resilient.